Solar DC Cables from PV Module to Array Junction Box

Single Core In Sq.Mm XL-LSOH Insulation Thickness - Nominal In Mm XL-LSOH Sheathing Thickness - Nominal In Mm Overall Dia. - Nominal In Mm Tinned Copper Max. Resistance @ 20C (Ohms-/Km) Current Carrying Capacity (Single Cable In Air) (In Amps-A)
1.5 0.5 0.5 4.10+/-0.5 13.700 300
2.5 0.5 0.5 4.10+/-0.5 8.210 41
4 0.5 0.5 5.1+/-0.5 5.090 55
6 0.5 0.5 6.1+/-0.5 3.390 70


Solar DC Cables from Array Junction Box to Main Junction Box & MJB to Inverter

Single Core In Sq.Mm XL-LSOH Insulation Thickness - Nominal In Mm XL-LSOH Sheathing Thickness - Nominal In Mm Overall Dia. - Nominal In Mm Tinned Copper Max. Resistance @ 20C (Ohms-/Km) Current Carrying Capacity (Single Cable In Air) (In Amps-A)
10 0.5 0.5 6.6+/-0.5 1.950 98
16 0.5 0.5 7.7+/-0.5 1.240 132
25 0.9 1.0 10.5+/-0.7 0.795 176
35 0.9 1.1 12.0+/-0.7 0.565 218
50 1.0 1.2 14.0+/-0.7 0.393 274
70 1.1 1.3 16.0+/-1.0 0.277 406
95 1.1 1.5 18.5+/-1.0 0.210 491
120 1.2 1.6 20.0+/-1.0 0.164 576
150 1.4 1.7 22.5+/-1.0 0.132 670
185 1.6 1.9 25.0+/-1.0 0.108 784
240 1.7 2.1 28.0+/-1.0 0.0817 944